Chapter 7 - Maintenance
NOTE: The frequency of these procedures will depend on the particular
system, its operating environment, and amount of usage. Use the times in
Table 7-2
NOTE: Special maintenance for the Cleanroom version of iCobra robots is
covered in
Special maintenance for the IP-65 version the Cobra i800 is covered in
Section 10.6 on page
7.3

Checking Safety Systems

It is recommended that tests be done every six months.
1. Test operation of:
• E-Stop button on Front Panel
• E-Stop button on T2
• Enabling switch on T2
• Auto/Manual switch on Front Panel
NOTE: Operating any of the above switches should disable High Power.
2. Test operation of all external (user-supplied) E-Stop buttons.
3. Test operation of barrier interlocks, etc.
7.4

Checking Robot Mounting Bolt Torque

Check the tightness of the base mounting bolts every 6 months. Tighten to 85 N·m
(63 ft·lb). Also check the tightness of all cover plate screws.
106
Adept Cobra i600/i800 Robot User's Guide, Rev E
as guidelines and modify the schedule as needed.
Section 9.5 on page
129.
141.
WARNING:
Lockout and tagout power before servicing.
WARNING:
The procedures and replacement of parts
mentioned in this section should be performed only by
skilled or instructed persons, as defined in
access covers on the robot are not interlocked – turn off
and disconnect power if covers have to be removed.