Figure 6-8 Cobra I600/I800 E-Stop Circuit Connections - adept technology Cobra i600 User Manual

Robot
Hide thumbs Also See for Cobra i600:
Table of Contents

Advertisement

Chapter 6 - System Operation
Cobra i600/i800
Internal Circuits
(Channel 2)
ESTOPGND
ESTOPSRC (Channel 1)
Manual Mode
Path
Auto Mode
Path
Force-Guided Relay
Cyclic Check
Control Circuit
Single-Phase
AC Input
200-240 VAC

Figure 6-8 Cobra i600/i800 E-Stop Circuit Connections

92
Adept Cobra i600/i800 Robot User's Guide, Rev E
Front Panel and T2 Circuits
XFP-2 (XPANEL-10)
XFP-1 (XPANEL-1)
XFP-9 (XPANEL-2)
XFP-10 (XPANEL-11)
XMCP-2 (XPANEL-15)
XMCP-1
(XPANEL-6)
XMCP-4 (XPANEL-17)
XMCP-3 (XPANEL-8)
XMCP-11 (XPANEL-9)
XMCP-12 (XPANEL-18)
XFP-4 (XPANEL-12)
XFP-3 (XPANEL-3)
Front Panel
High Power ON/OFF
XFP-6 (XPANEL-19)
6 V, 1.2 W
XFP-5 (XPANEL-5)
bulb
XFP-13 (XPANEL-21)
XFP-14 (XPANEL-20)
Force-Guided
Relay
User-Supplied Circuits
NOTE: The "Line E-Stop" and
Front Panel
"User Manual/Auto Indication"
ESTOP
functions of the XUSR connector
Pushbutton
are not supported on the
Cobra i600/i800 robots.
User E-Stop and Gate Interlock
(Jumper closed when not used,
T2 ESTOP
MUST open both channels
Pushbutton
independently if used.)
XUSR-2
XUSR-1
XUSR-14 (XPANEL-7)
XUSR-15 (XPANEL-16)
T2-4
3-Position
Enable Switch
Front Panel
Manual/Auto
Keyswitch
XUSR-6
XUSR-5
XUSR-18
(XPANEL-4)
XUSR-19
(XPANEL-13)
High Power to
Amplifiers
Force-Guided
Relay
Muted Safety Gate -
Active in Auto mode only
(Jumper closed when
not used.)