Figure 5-14. Configuration Manager - Modifying Joint 1 Limits - adept technology Cobra i600 User Manual

Robot
Hide thumbs Also See for Cobra i600:
Table of Contents

Advertisement

3. Click on Joint 1.
The following screen opens to allow editing the limits:

Figure 5-14. Configuration Manager - Modifying Joint 1 Limits

4. In the Lower Limit field, enter the new value for the J1 lower limit softstop. See
the following table for recommended softstop values for Position 1 or Position 2.
Note that this value must be a negative number.
Table 5-7. Joint 1 Ranges for Adjustable Hardstops
J1 Hardstop Position 1
J1 Hardstop Position 2
5. In the Upper Limit field, enter the new value for the J1 upper limit softstop. See
the preceding table for recommended softstop values for Position 1 or Position 2.
6. Click Apply. The Apply Changes window opens, as illustrated in
7. Select the required options for saving joint limit values to temporary or
permanent memory. For more information on saving changes, click Help
8. Click Write to apply and save the changes.
Adept Cobra i600/i800 Robot User's Guide, Rev E
Installing Adjustable Hardstops
Hardstop Value
± 50°
± 88°
Recommended
Joint Limit
Softstop
Lower limit: – 49°
Upper limit: + 49°
Lower limit: – 87°
Upper limit: + 87°
Figure
5-15.