Cable Installation (Model 3303, with two power chassis)

The extra VJI module and two amplifier modules require additional cables that are
shipped with the system. It is important to keep the cables organized and prevent cables
from being interchanged by mistake. The table below shows a typical arrangement for
cable assignments.
Typical Robot-VJI-Amplifier Assignments in Dual Adept 550 Robot System
Table C-1.
Robot Number
1
2
Make sure to clearly label or mark the cables so it will be obvious which robot they belong
to, in case the cables have to be disconnected and re-installed.
C.3 Operation with the Manual Control Pendant (MCP)
The optional MCP can be used to control either robot in a Dual Adept 550 robot system.
By default, the MCP controls robot 1. To switch to robot 2, press the DEV/F3 button on the
MCP. The DEV2 LED turns on in this condition.
To switch back to robot 1, press the DEV/F3 button again. The DEV2 LED turns off.
See the Manual Control Pendant User's Guide for more information on using the MCP.

C.4 Programming Information

+
V

Language Programming

By default, Task 0 is used to control robot 1. Task 1 is normally recommended for robot 2.
Use the SELECT ROBOT=2 and ATTACH instructions in your program to select robot 2.
+
See the V
Language User's Guide and the V
on these instructions.
+
V

Monitor Commands

By default, monitor commands such as HERE and WHERE apply to robot 1. Use the mon-
itor command SELECT ROBOT=2 first when you need to display the location of robot 2.
NOTE: The DISABLE POWER command shuts off high power to both
robots in a Dual Adept 550 robot system.
The CALIBRATE monitor command will calibrate both robots. Robot 1 will be calibrated
first, then robot 2.
Adept 550 Table-Top Robot User's Guide, Rev A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Operation with the Manual Control Pendant (MCP)

VJI Module
Power Chassis
1 (Left)
2 (Right)
+
Language Reference Guide for more information
Amplifier
Module
1
1, 2
2
1, 2
73