Commissioning
Table 38: "Port Mode" Drop-Down Menu: Selecting the Operating Mode for Pin 2 and Pin 4 of the Selected IO-
Selection Option
Digital Output
Digital output, static on
Setting the Filter Time for Digital Inputs
The filter time for the digital inputs can be selected from the Digital input signal filter
drop-down menu. You can select from the following values:
• No digital input filter
• 3 ms
• 15 ms
• 20 ms
If the No digital input filter option is selected, no filtering occurs.

10.3.1.4.2 Configuring IP Parameters

The Device configuration tab allows you to do the following:
• Specify how the module gets its IP address (via the Configuration control drop-down
menu with the STATIC, BOOTP und DHCP options)
#
0
1
2
64
Product manual | Version: 2.0.0
16DO FLD EI DC 24V 2.0A
Description
The port is used as a digital output. All elements of the port configuration are ig-
nored except for the input and output data length.
The port is used as a digital output. The signal on pin 2 or pin 4 is permanently set
to logic 1.
Figure 16: Settings Menu Item, Device Configuration Tab (Example View)
Option
Description
STATIC
The module's IP address is configured statically. This is done using the module IP ad-
dress, the subnet mask and the gateway IP address entered on the "Device configura-
tion" tab.
BOOTP
The module gets its IP address with the BOOTP protocol.
DHCP
The module gets its IP address with the DHCP protocol. This is the standard setting.
Table 39: Configuration Control Drop-Down Menu
765-1503/100-000