Pest Error Reporting - Xerox Phaser 8400 Service Manual

Hide thumbs Also See for Phaser 8400:
Table of Contents

Advertisement

POST Error Reporting Blink Pattern Definition Table (Continued)
8400
Control
PS, PE and
Panel
Control
Error
Panel LEDs
Code
(for 8400)
16.04
Flutter only
17.01
Flutter and
then 17
blinks
18.01
Flutter and
then 18
blinks
18.02
Flutter and
then 18
blinks
18.03
Flutter and
then 18
blinks
18.04
Flutter only
19.01
Flutter and
then 19
blinks

PEST Error Reporting

PEST tests occur after POST tests have been run and PostScript has been initialized.
PEST checks the connections and operation of various printer components.
Error codes for PEST tests are displayed on the Control Panel and are all in the
37,XXX.xx series. For troubleshooting PEST error codes, "37,0XX.xx Errors - PEST
Faults" on page 3-41.
3-8
POST
Error
Type
Description
Soft
Real-time clock does not tick.
Soft
Trickle charge failure
Hard
Memory test, less than 128 MB of RAM
detected. This is the minimum RAM
required. Add more RAM. Reseat the RAM
SODIMM(s), then replace the RAM
SODIMM(s).
Hard
IPCB ID read failure.
Hard
IPCB ID mismatch.
Hard
IPCB PCI configuration failure.
Soft
IPCB version mismatch.
Hard
Check and reseat cables. Replace hard
drive, if necessary.
Phaser 8400/8500/8550 Color Printer
8500/
8550
Control
Panel
Error
Code
11.4
11.5
13.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 8550Phaser 8500

Table of Contents