Service Parts Disassembly
Print Engine Solenoids and Sensors
Tray 1 Paper Pick Solenoid (PL4.20.20)
8-102
1.
Remove the High Voltage Unit (page 8-50).
2.
Remove 1 screw (metal, 10mm), unlock the tab, and release the wiring
clamp from the saddle. Then, remove the shield.
Clamp
Caution
When reinstalling the shield, make sure that no part of the harness is
wedged in the mechanism.
3.
Remove 1 screw (metal, 8mm) and disconnect connector (CN2).
Tab
Phaser 6115MFP Multifunction Product Service Manual
Shield
s6115-305