When the math operation type is FFT (refer to the :CALCulate:MODE command), <chan> cannot be
set to "MATH".
When [<chan>] is omitted, the command, by default, applies to the currently set measurement source
(refer to the :MEASure:SOURce command).
Return Format
The query returns the average value, current value, standard deviation, maximum value, or minimum value
in scientific notation. When the measurement results are invalid, the query returns 9.9e37.

:MEASure:PVRMs

Syntax 1
:MEASure:PVRMs <chan>
Description 1
Measures the period amplitude effective value (Per. Vrms) of the specified source channel.
Syntax 2
:MEASure:PVRMs? <chan>
Description 2
Measures and queries the period amplitude effective value (Per. Vrms) of the specified source channel. The
unit is related to the current amplitude unit of the specified source channel.
Parameter
Name
Type
<chan>
Discrete
Remarks
Period amplitude effective value (Per. Vrms): indicates the amplitude root mean square value of a
single period of waveform within the current measurement range (refer to the :MEASure:AREA
command).
Before making measurements, turn on the channels to be measured.
When the math operation type is FFT (refer to the :CALCulate:MODE command), <chan> cannot be
set to "MATH".
When [<chan>] is omitted, the command, by default, applies to the currently set measurement source
(refer to the :MEASure:SOURce command).
Return Format
The query returns the measurement results in scientific notation. When the measurement results are
invalid, the query returns 9.9e37.
:MEASure:PVRMs:SAVerage
:MEASure:PVRMs:SCURrent
:MEASure:PVRMs:SDEViation
:MEASure:PVRMs:SMAXimum
:MEASure:PVRMs:SMINimum
Syntax 1
:MEASure:PVRMs:SAVerage [<chan>]
:MEASure:PVRMs:SCURrent [<chan>]
:MEASure:PVRMs:SDEViation [<chan>]
:MEASure:PVRMs:SMAXimum [<chan>]
:MEASure:PVRMs:SMINimum [<chan>]
2-140
Range
{CHANnel1|CHANnel2|CHANnel3|CHANnel4|MATH}
Chapter 2 Command System
Default
--