Detailed Parameters 2 - Mitsubishi Electric MELSEC-Q Series User Manual

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

5.2.4 Detailed parameters 2

Item
[Pr.25] Acceleration time 1
[Pr.26] Acceleration time 2
[Pr.27] Acceleration time 3
[Pr.28] Deceleration time 1
[Pr.29] Deceleration time 2
[Pr.30] Deceleration time 3
[Pr.31]
JOG speed limit value
[Pr.32]
JOG operation acceleration
time selection
[Pr.33]
JOG operation deceleration
time selection
[Pr.34]
Acceleration/deceleration
process selection
[Pr.35]
S-curve ratio
[Pr.36]
Rapid stop deceleration
time
[Pr.37]
Stop group 1 rapid stop
selection
[Pr.38]
Stop group 2 rapid stop
selection
[Pr.39]
Stop group 3 rapid stop
selection
[Pr.40]
Positioning complete signal
output time
Setting value, setting range
Value set with GX Works2
1 to 8388608 (ms)
The setting range differs depending on the "[Pr.1] Unit setting".
0: [Pr.9] Acceleration time 0
1: [Pr.25] Acceleration time 1
2: [Pr.26] Acceleration time 2
3: [Pr.27] Acceleration time 3
0: [Pr.10] Deceleration time 0
1: [Pr.28] Deceleration time 1
2: [Pr.29] Deceleration time 2
3: [Pr.30] Deceleration time 3
0: Trapezoid acceleration/
deceleration process
1: S-curve acceleration/
deceleration process
1 to 100 (%)
1 to 8388608 (ms)
0: Normal deceleration stop
1: Rapid stop
0 to 65535 (ms)
Chapter 5 Data Used for Positioning Control
Value set with sequence
program
1 to 8388608 (ms)
0
1
2
3
0
1
2
3
0
1
1 to 100 (%)
1 to 8388608 (ms)
0
1
0 to 65535 (ms)
0 to 32767
: Set as a
decimal
32768 to 65535 : Convert into
hexadecimal
and set
5 - 38
Default
Buffer memory address
value
36+150n
37+150n
38+150n
39+150n
40+150n
41+150n
1000
42+150n
43+150n
44+150n
45+150n
46+150n
47+150n
48+150n
20000
49+150n
0
50+150n
0
51+150n
0
52+150n
100
53+150n
54+150n
1000
55+150n
56+150n
0
57+150n
58+150n
300
59+150n
n: Axis No.-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents