14.2 Parameter initialization function

The "parameter initialization function" is used to return the setting data set in the buffer
memory/internal memory and flash ROM/internal memory (nonvolatile) of Simple
Motion module to their factory-set initial values.
The details shown below explain about the "parameter initialization function".
[1] Parameter initialization means
[2] Control details
[3] Precautions during control
[4] Parameter initialization method
[1] Parameter initialization means
• Initialization is executed with a sequence program.
• Initialization is executed by GX Works2.
Refer to the "Simple Motion Module Setting Tool Help" of GX Works2 for the
execution method by GX Works2.
[2] Control details
The following table shows the setting data initialized by the "parameter
initialization function".
(The data initialized are "buffer memory/internal memory" and " flash
ROM/internal memory (nonvolatile)" setting data.)
Basic parameters ([Pr.1] to [Pr.10])
Detailed parameters ([Pr.11] to [Pr.42], [Pr.80] to [Pr.90], [Pr.95])
HPR basic parameters ([Pr.43] to [Pr.48])
HPR detailed parameters ([Pr.50] to [Pr.57])
Expansion parameters ([Pr.96], [Pr.113], [Pr.132])
Servo parameters ([Pr.101],
MR-J4-B use: PA, PB, PC, PD, PE, PS, PF, Po, PL)
Positioning data (No.1 to 600)
Block start data (No.7000 to 7004)
1: Initialized regardless of the status of "[Pr.132] Communication mode setting" at the
parameter initialization.
Setting data
14 - 3
Chapter 14 Common Functions