Related buffer memory address
Refer to Section 5.3
"List of positioning data"
ABS setting direction in the unit
of degree
4350+100n
Software stroke limit
upper limit
18+150n
19+150n
Software stroke limit
lower limit
20+150n
21+150n
Operation setting for
incompletion of HPR
87+150n
5901
Set range
(Setting with sequence program)
<Maximum radius>
536870912
<LOOP to LEND>
1 to 65535
0: Shortcut
1: Clockwise
2: Counterclockwise
• [mm] [inch] [PLS]
–2147483648 to 2147483647
• [degree]
0 to 35999999
<Operation setting for incompletion of
HPR>
0, 1
<Parameter initialization request>
1: Parameter initialization is requested
16 - 29
Chapter 16 Troubleshooting
Remedy
Correct the positioning data.
(Refer to Section 9.2.10 or 9.2.11)
Set 1 to 65535 in the repeating time of LOOP. (Refer to
Section 9.2.22)
• Set the ABS setting direction in the unit of degree within the
setting range.
• Set "0" when the software stroke limits are valid. (Refer to
Section 9.1.5)
Invalidate the software stroke limit.
(To invalidate, set the software stroke limit upper limit value to
the software stroke limit lower limit value.)
(Refer to Section 9.1.5)
• Start after the HPR is executed.
• Switch the control mode after the HPR is executed.
• For systems which can operate the positioning control and
speed-torque control though the HPR request is ON, set "1"
to the setting value of the operation setting at HPR
incomplete.
Use a servo amplifier which supports the speed-torque
control.
Clear the setting of the CPU module parameter "Output at
error stop".
The flash ROM is expected to be at the end of its writable life.
Return the parameter to that set at the time of delivery from
the plant. (Refer to Section 14.2)
n: Axis No.-1