Set with a decimal.
Setting
K
value
Set with a decimal.
Setting
K
value
Set with a hexadecimal.
Setting
H
value
b15
b12
b8
Buffer
memory
Buffer
Setting items
memory
b0
Axis 1 Upper limit signal (FLS)
Axis 1 Lower limit signal (RLS)
b1
b2
Axis 1 Proximity dog signal (DOG)
b3
Axis 1 STOP signal (STOP)
b4
Axis 2 Upper limit signal (FLS)
b5
Axis 2 Lower limit signal (RLS)
b6
Axis 2 Proximity dog signal (DOG)
b7
Axis 2 STOP signal (STOP)
5928
Axis 3 Upper limit signal (FLS)
b8
b9
Axis 3 Lower limit signal (RLS)
b10
Axis 3 Proximity dog signal (DOG)
b11
Axis 3 STOP signal (STOP)
b12
Axis 4 Upper limit signal (FLS)
b13
Axis 4 Lower limit signal (RLS)
b14
Axis 4 Proximity dog signal (DOG)
b15
Axis 4 STOP signal (STOP)
b0
Axis 5 Upper limit signal (FLS)
b1
Axis 5 Lower limit signal (RLS)
b2
Axis 5 Proximity dog signal (DOG)
b3
Axis 5 STOP signal (STOP)
b4
Axis 6 Upper limit signal (FLS)
b5
Axis 6 Lower limit signal (RLS)
b6
Axis 6 Proximity dog signal (DOG)
b7
Axis 6 STOP signal (STOP)
5929
b8
Axis 7 Upper limit signal (FLS)
b9
Axis 7 Lower limit signal (RLS)
b10
Axis 7 Proximity dog signal (DOG)
b11
Axis 7 STOP signal (STOP)
b12
Axis 8 Upper limit signal (FLS)
b13
Axis 8 Lower limit signal (RLS)
b14
Axis 8 Proximity dog signal (DOG)
b15
Axis 8 STOP signal (STOP)
Setting value
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
Stop command processing for deceleration
stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
b4
b0
Default
Buffer
Meaning
Setting items
value
memory
0
b0
Axis 9 Upper limit signal (FLS)
0
Axis 9 Lower limit signal (RLS)
b1
0
b2
Axis 9 Proximity dog signal (DOG)
0
b3
Axis 9 STOP signal (STOP)
0
b4
Axis 10 Upper limit signal (FLS)
0
b5
Axis 10 Lower limit signal (RLS)
0
b6
Axis 10 Proximity dog signal (DOG)
0
b7
Axis 10 STOP signal (STOP)
5930
0
Axis 11 Upper limit signal (FLS)
b8
0
b9
Axis 11 Lower limit signal (RLS)
"
Pr.22
0
b10
Axis 11 Proximity dog signal (DOG)
Input
0
signal logic
b11
Axis 11 STOP signal (STOP)
selection"
0
b12
Axis 12 Upper limit signal (FLS)
is negative
0
b13
Axis 12 Lower limit signal (RLS)
logic
0: OFF
0
b14
Axis 12 Proximity dog signal (DOG)
1: ON
0
b15
Axis 12 STOP signal (STOP)
0
b0
Axis 13 Upper limit signal (FLS)
"
Pr.22
Input
0
b1
Axis 13 Lower limit signal (RLS)
signal logic
0
b2
Axis 13 Proximity dog signal (DOG)
selection"
0
b3
Axis 13 STOP signal (STOP)
is positive
logic
0
b4
Axis 14 Upper limit signal (FLS)
0: ON
0
b5
Axis 14 Lower limit signal (RLS)
1: OFF
0
b6
Axis 14 Proximity dog signal (DOG)
0
b7
Axis 14 STOP signal (STOP)
5931
0
b8
Axis 15 Upper limit signal (FLS)
0
b9
Axis 15 Lower limit signal (RLS)
0
b10
Axis 15 Proximity dog signal (DOG)
0
b11
Axis 15 STOP signal (STOP)
0
b12
Axis 16 Upper limit signal (FLS)
0
b13
Axis 16 Lower limit signal (RLS)
0
b14
Axis 16 Proximity dog signal (DOG)
0
b15
Axis 16 STOP signal (STOP)
5 - 133
Chapter 5 Data Used for Positioning Control
Default
Buffer memory address
value
0
0
Default
Meaning
value
0
0
0
0
0
0
0
0
0
0
0000H
"
Pr.22
0
Input
0
signal logic
selection"
0
is negative
0
logic
0: OFF
0
1: ON
0
0
"
Pr.22
Input
0
signal logic
0
selection"
0
is positive
logic
0
0: ON
0
1: OFF
0
0
0
0
0
0
0
0
0
0
5905
5907
5928
to
5931