(3) When the stop command was given to make a stop after a speed change
V
Speed change
command
Fig. 13.24 Restarting speed after speed change made during position control
(4) When the speed is changed by setting "[Cd.14] New speed value" to "0", the
Positioning start signal
[Y10 to Y1F]
BUSY signal
[X10 to X1F]
Cd. 14 New speed value
Cd. 15 Speed change request
Positioning operation
Speed change 0 flag
( Md. 31 status: b10)
Fig. 13.25 Speed change at new speed value "0"
that had been made during position control, the restarting speed depends
on the "[Cd.14] New speed value".
Restarting
command
Stop command
operation is carried out as follows.
When "[Cd.15] Speed change request" is turned ON, the speed change 0
flag ([Md.31] Status: b10) turns ON.
(During interpolation control, the speed change 0 flag on the reference axis
side turns ON.)
The axis stops, but "[Md.26] Axis operation status" does not change, and
the BUSY signal remains ON. (If a stop signal is input, the BUSY signal
will turn OFF, and "[Md.26] Axis operation status" will change to
"stopped".)
In this case, setting the "[Cd.14] New speed value" to a value besides "0"
will turn OFF the speed change 0 flag ([Md.31] Status: b10), and enable
continued operation.
ON
OFF
ON
OFF
0
ON
OFF
ON
OFF
13 - 46
Chapter 13 Control Sub Functions
Da. 8
Command speed
Cd. 14 New speed value
t
1000