5.1.10 Types and roles of control data

Write setting data from buffer memory to flash ROM.
Reset (initialize) parameters.
Operation of the positioning system is achieved through the execution of necessary
controls. (Data required for controls are given through the default values when the
power is switched ON, which can be modified as required by the sequence program.)
Items that can be controlled are described below.
Controlling the system data :
Setting and resetting "setting data" of Simple Motion module (system control data
[Cd.1], [Cd.2])
Controlling the operation :
Setting operation parameters, changing speed during operation, interrupting or
restarting operation, etc. (system control data [Cd.41], [Cd.42], [Cd.44], axis control
data [Cd.3] to [Cd.40], [Cd.43], [Cd.45], [Cd.46], [Cd.100], [Cd.101], [Cd.108],
[Cd.112], [Cd.113], [Cd.133], [Cd.136], [Cd.138] to [Cd.146], [Cd.180] to [Cd.183])
[1] Controlling the system data
Setting and resetting the setting data
Control details
Chapter 5 Data Used for Positioning Control
[Cd.1]
Flash ROM write request
[Cd.2]
Parameter initialization request
5 - 16
Controlled data item