Mitsubishi Electric MELSEC-Q Series User Manual page 216

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Storage item
Storage details
Stores an axis No. in which an
[Md.9]
error occurred.
Axis in which
the error
occurred
Refresh cycle: Immediate
Stores an axis error No.
[Md.10]
Axis error No.
Refresh cycle: Immediate
Stores the details of servo
amplifier detection alarm. ("0" is
stored other than when a servo
[Md.57]
alarm occurs.)
Servo alarm
Refresh cycle: Immediate
Stores the time (Year: month) at
[Md.55]
which an axis error was detected.
Axis error
occurrence
Refresh cycle: Immediate
(Year: month)
[Md.11]
Stores the time (Day: hour) at
which an axis error was detected.
Axis error
occurrence
(Day: hour)
Refresh cycle: Immediate
[Md.12]
Stores the time (Minute: second)
at which an axis error was
Axis error
detected.
occurrence
(Minute:
second)
Refresh cycle: Immediate
Indicates a pointer No. that is
next to the pointer No. assigned
[Md.13]
to the latest of the existing
Error history
records.
pointer
Refresh cycle: Immediate
Chapter 5 Data Used for Positioning Control
Reading the monitor value
Monitoring is carried out with a decimal display.
Monitor
value
Monitoring is carried out with a decimal display.
Monitor value
Monitoring is carried out with a hexadecimal display.
Monitor
value
Monitoring is carried out with a hexadecimal display.
Buffer memory (stored with BCD code)
0
8
0
6
b15
b12
b8
b4
b0
0
0 0 0 1 0 0 0 0 0 0 0 0 1 1 0
0 to 9
0 to 9
0 to 1
0 to 9
Monitoring is carried out with a hexadecimal display.
Buffer memory (stored with BCD code)
2
8
1
5
b15
b12
b8
b4
b0
0
0 1 0 1 0 0 0 0 0 0 1 0 1 0 1
0 to 3
0 to 9
0 to 2
0 to 9
Monitoring is carried out with a hexadecimal display.
Buffer memory (stored with BCD code)
4
9
0
7
b15
b12
b8
b4
b0
0
1 0 0 1 0 0 1 0 0 0 0 0 1 1 1
0 to 5
0 to 9
0 to 5
0 to 9
Monitoring is carried out with a decimal display.
Monitor value
5 - 96
Storage value
1: Axis 1
5: Axis 5
9: Axis 9
13 : Axis 13
2: Axis 2
6: Axis 6 10: Axis 10
14: Axis 14
3: Axis 3
7: Axis 7 11: Axis 11
15: Axis 15
4: Axis 4
8: Axis 8 12: Axis 12
16: Axis 16
Axis error No.
For details of error codes,
refer to Section 16.4
"List of errors".
Servo alarm code
Monitor value
0
8
0
6
00 to 99 (year)
01 to 12 (month)
Monitor value
2
8
1
5
01 to 31 (day)
00 to 23 (hour)
Monitor value
4
9
0
7
00 to 59 (minute) 00 to 59 (second)
Storage value
(Pointer number)
0 to 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents