Mitsubishi Electric MELSEC-Q Series User Manual page 243

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Reading the monitor value
Monitoring is carried out with a decimal display.
Monitor value
Monitoring is carried out with a hexadecimal display.
b15
b12
b8
Monitoring is carried out with a hexadecimal display.
b15
b12
b8
POINT
(1) When the forced stop of controller and servo amplifier occurs, the servo
warning is turned ON. When the forced stop is reset, the servo warning is
turned OFF.
Storage value
Storage value Parameter No.
1 to 64
PA01 to PA64
64 to 128
PB01 to PB64
129 to 192
PC01 to PC64
193 to 256
PD01 to PD64
257 to 320
PE01 to PE64
321 to 384
PF01 to PF64
385 to 448
Po01 to Po64
449 to 512
PS01 to PS64
513 to 576
PL01 to PL64
b4
b0
Stored items
b0
Zero point pass
Zero speed
b3
b4 Speed limit
b8 PID control
b4
b0
Stored items
b0
READY ON
b1
Servo ON
b2
Control mode
b3
b4
Gain switching
Fully closed loop
b5
control
b7
Servo alarm
b12
In-position
b13
Torque limit
b14
Absolute position lost
b15
Servo warning
: Control mode
b2
b3
0
0
Position control mode
1
0
Speed control mode
0
1
Torque control mode
5 - 123
Chapter 5 Data Used for Positioning Control
Default
value
0
Meaning
0000H
0: OFF
1: ON
Meaning
0: OFF
1: ON
0000H
Control mode
Buffer memory address
2470+100n
2476+100n
2477+100n
n: Axis No.-1