Mitsubishi Electric MELSEC-Q Series User Manual page 198

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

[Da.2] setting value
JUMP instruction: 82H
Other than JUMP instruction
LOOP: 83H
[Da.10] M code/Condition data No./Number of LOOP to LEND repetitions
Set an "M code", a "condition data No.", or the "Number of LOOP to LEND
repetitions" depending on how the "[Da.2] Control method" is set.
If a method other than "JUMP instruction" and "LOOP" is selected as the
"[Da.2] Control method"
............... Set an "M code".
If no "M code" needs to be output, set "0" (default value).
If "JUMP instruction" or "LOOP" is selected as the "[Da.2] Control method"
............... Set the "condition data No." for JUMP.
0
1 to 10 : JUMP performed according to the condition data No.
Make sure that you specify the number of LOOP to LEND repetitions
by a number other than "0". The error "Control method LOOP setting
error" (error code: 545) will occur if you specify "0".
1: The condition data specifies the condition for the JUMP instruction to be
executed.
(A JUMP will take place when the condition is satisfied.)
Setting item
Condition data No.
M code
Repetition count
Chapter 5 Data Used for Positioning Control
: Unconditional JUMP to the positioning data specified by
[Da.9].
specified (a number between 1 and 10).
Value set with GX Works2
0 to 65535
1 to 65535
5 - 78
Value set with sequence
0 to 10
1
program
0 to 10
0 to 65535
1 to 65535