[Operation example]
The following operation assumes that the speed-position switching signal is input at the position of the
feed current value of 90.00000 [degree] during execution of "[Da.2] Control method" "Forward run:
speed/position" at "[Pr.1] Unit setting" of "2: degree" and "[Pr.21] Feed current value during speed
control" setting of "1: Update feed current value".
(The value set in "[Da.6] Positioning address/movement amount" is 270.00000 [degree])
Positioning start signal
[Y10 to Y1F]
BUSY signal
[X10 to X1F]
M code ON signal
( Md.31 Status: b12)
(WITH mode)
Cd.7 M code OFF request
Start complete signal
( Md.31 Status: b14)
Md.26 Axis operation status
Positioning operation
Speed-position switching
command
Cd. 23 Speed-position switching
control movement amount
change register
Positioning complete signal
( Md.31 Status: b15)
M code ON signal (AFTER mode)
( Md.31 Status: b12)
Cd.7 M code OFF request
HPR complete flag
( Md.31 Status: b4)
Fig. 9.14 Operation timing and processing time during speed-position switching control (INC mode)
Speed-position
0.00000
switching signal ON
90.00000
Operation timing and processing time during speed-position switching
control (INC mode)
t1
Standby
Speed control
t4
0.00000
90.00000
t2
Position control
Standby
Speed
Position
control
control
Speed control carried out until speed-position switching
signal turns ON
Position control movement amount is from the input position of
the external speed-position switching signal
t6
t5
9 - 92
Chapter 9 Major Positioning Control
90.00000+270.00000
=360.00000
=Stop at 0.00000 [degree]
t3
t7
t2