Chapter 2—Configuring and Managing the Terminals
14
If you want to save your changes after you boot or reset the terminal, you
must save them in the terminal's flash memory. For help, see "Saving
Configuration Changes in Flash Memory" on page 29.
To configure the terminal, you can scan separate bar code labels, or you
can create bar code labels that contain more than one configuration
command. For example, you can create one bar code label to configure the
terminal for:
• One-Shot Scanner mode (SB0)
• Scanner Redundancy set to high (SR2)
• Beep Volume set to very loud (BV4)
• Disable Keypad Clicker (KC0)
One-Shot Scanner Mode, Set Scanner Redundancy to High,
Set Beep Volume to Very Loud, Disable Keypad Clicker
*$+SB0SR2BV4KC0*
*$+SB0SR2BV4KC0*
When you create a bar code label to set several configuration commands,
follow these rules:
• The bar code label must be printed using Code 39 or Code 93
symbology. If you need to scan a Code 39 bar code label that includes
quotes or periods, you must configure the terminal to use Code 39 in
Full ASCII mode.
• The bar code label must include the start and stop character. Most bar
code printing utilities automatically include the start and stop character.
• The bar code label must start with $+ (Change Configuration
command).
• Each configuration command must include the command syntax and
the value for the command. For example, BV is the command syntax for
Beep Volume and the value 4 sets the beep volume to very loud.
• If you set one configuration command to a string of ASCII characters
and another configuration command follows, you must enclose the
value in quotes. If you do not include the quotation marks, the terminal
will interpret everything after the first command as data and will not
find the second configuration command.
• For example, to set the preamble to BV, use $+ADBV (no quotes are
needed). To set the preamble to BV and turn off the beep volume, use
$+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear
the preamble and postamble from a single label, use $+AD""AE.
• To include quotation marks when you set a value, the entire value must
be enclosed in quotation marks. Type two sets of quotation marks ("")
to include one quotation mark as the value for a command. For
example, to set the preamble to ABC"D, use $+AD"ABC""D".