Chapter 4—Running Diagnostics
Error Numbers and Messages (continued)
Error
Number
Message
0x202
Invalid Decodes command
0x203
Invalid Decode symbology specified
0x204
Unable to decode input scan
0x205
Missing start or stop character
0x206
Number of counts less than minimum
0x207
Invalid character found
0x208
Invalid acceleration between characters
0x20A
Label length less than minimum
0x20B
Incorrect check digit
0x20C
Output string too short
0x20D
Leading margin not found
0x20E
Invalid start or stop pattern
0x20F
Not enough counts for whole label
0x210
Missing trailing margin
0x211
Invalid supplement to UPC label
0x212
Parity error while decoding character
0x213
Guard character not found
0x214
Invalid row number (Code 49 or Code
16K)
0x215
Unable to scale counts buffer
0x216
Error in 2 of 5 label
0x217
Wrong length 2 of 5 label
0x218
Longer than maximum 2 of 5 label
length
0x219
Valid label region not found
0x21A
Ink spread exceeded threshold
0x21B
The denominator of an expression is 0
0x21C
ASCIIfication of Full ASCII failed
90
39 AGaramond
nugget
Error
Number
0x21D
0x21E
0x21E
0x21F
0x221
0x222
0x223
0x224
0x225
0x226
0x227
0x228
0x22A
0x22B
0x22C
0x22D
0x22E
0x230
0x231
0x241
0x250
0x251
0x260
0x261
0x262
0x263
Message
Raw scan buffer. No decode attempted yet
Error upgrading Flash on a Scanner Module
Field is full no more input allowed until this is
returned
Address not in the application data space
range.
Movement direction parameter invalid, not
one of four viewport directions
End of display block outside virtual display
A printable keycode was passed in a command
to set manual movement
Both start and end outside of virtual display
First parameter to function invalid
Invalid com source number i.e. > E_NET
Input requested with no valid source to
receive it from
Start of display block outside virtual display
PSK coding error
Network error
No description available
Informational: Follow Cursor mode not
enabled
The cursor detection value in a set follow
cursor command is larger than the viewport
size
The viewport movement value is larger than
the viewport size
Data transmitted before cancel request
accepted
Data entered does not match mask type
NMI for keypad received prior to vector
NMI for PMU received prior to vector
SpOpen not previously called successfully
The port handle is unknown to CSP
Control block pointer is NULL
Port is not valid