Chapter 6—Configuration Command Reference
Syntax: YEn.data
Default: 10 seconds
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial
Bar Codes: To set the default timeout delay, scan one of these bar codes:
Or: To set the timeout delay for one serial port:
258
Note: Before you can set Timeout Delay, you need to configure the EOM
and Handshake commands.
where n is:
1
COM1 serial port
2
COM2 serial port (246X and 248X terminals only)
3
COM3 serial port (242X terminals only)
4
COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are:
0
5 ms
1
100 ms
2
500 ms
3
2 sec
4
10 sec
5
20 sec
6
40 sec
7
60 sec
Port
Timeout Delay 10 sec for COM1
*$+YE1.4*
.
*$+YE1
4*
Timeout Delay 10 sec for COM3
*$+YE3.4*
.
*$+YE3
4*
1 Scan this bar code:
Enter Accumulate Mode / Set Timeout Delay
*+/$+YE*
*+/$+YE*
2 Scan the serial port from these bar codes:
COM1
*1.*
.
*1
*
Timeout Delay 10 sec for COM2
*$+YE2.4*
.
*$+YE2
4*
Timeout Delay 10 sec for COM4
*$+YE4.4*
.
*$+YE4
4*
COM2
*2.*
.
*2
*
Trakker Antares 2400 Family System Manual