Intermec Trakker Antares 2410 System Manual page 168

Intermec trakker antares 2410: user guide
Hide thumbs Also See for Trakker Antares 2410:
Table of Contents

Advertisement

Chapter 6—Configuration Command Reference
Syntax: CBdata
Default: Enable Code 39 Full ASCII with no check digit (111)
Menu System: Main Menu > Configuration Menu > Symbologies Menu > Code 39
Bar Codes: To disable Code 39, scan this bar code:
Or: To enable Code 39:
148
Use this table to help configure your terminal.
Code 39 ASCII Decodes
Code 39 Option
Non-full ASCII
Full ASCII
Mixed-full ASCII
Acceptable values for data must be three digits, corresponding to:
Digit 1:
0
Disabled
1
Enabled with no check digit
2
Enabled with check digit
3
HIBC (Health Industry Bar Code)
4
With AIAG check digit
Digit 2:
0
Discard check digit
1
Retain check digit
Digit 3:
0
Code 39 non-full ASCII
1
Code 39 full ASCII
2
Code 39 mixed-full ASCII
Note: Selecting HIBC Code 39 automatically sets the configuration to
non-full ASCII with the check digit transmitted. HIBC and With AIAG
check digit are not supported on terminals with an integrated E1022 linear
imager or an integrated PDF417 scan engine.
Disable Code 39
*$+CB0*
*$+CB0*
1 Scan this bar code:
Enter Accumulate Mode / Enable Code 39
*+/$+CB*
*+/$+CB*
Bar Code Label
Decodes
$%+A
$%+A
/D/E+A
/D/E+A
$%+A
No decode
/D/E+A
$%a
$%+A
$%a
/D/E+A
$%a
Trakker Antares 2400 Family System Manual