HindlePower ATevo Series Operations page 31

Float battery charger phase input–group ii (30-100 adc output)
Table of Contents

Advertisement

HindlePower Inc
utilize a Capacitor Board (A7) bolted to the top of the Power Board (A2). ATevo units rated
75-100A utilize a bank of discrete capacitors (C1x), hardwired to the Power Board (A2) with
bolted connections.
A9-
A9-A A C Sur
C Surge Suppr
ge Suppressor
essor MO
Shown to left of AC Circuit Breaker (CB1) on silkscreen. Mounted to top-left side of breaker
bracket. Contains ac input surge suppression and filtering. It is located for easy access,
examination, and replacement in case an input transient event should occur.
A10-R
A10-Remote T
emote Temperatur
emperature P
The battery temperature compensation, or 'TempCo', probe (A10) contains a temperature-
dependent resistor in an epoxy module. When used, this probe is installed on the battery and is
connected to the Power Board (A2) at TB8.
A12-Serial Communications A
A12-Serial Communications Adapter
Shown above Ethernet Comm. Adapter (A22) on silkscreen. Up to three (3) Serial
Communications Adapter boards (A12) can be plugged into the Main Control Board (A1) at
locations P10, P11, and P12. This option supports DNP3 and Modbus protocols, and can be
configured to support 2-wire or 4-wire RS-232 connections, or 2-wire or 4-wire RS-485
connections.
A13-F
A13-For orced L
ced Load Sharing Communications A
oad Sharing Communications Adapter – optional
Mounted similarly to Serial Communications Adapter (A12).
A22-Ether
A22-Ethernet Communications A
net Communications Adapter – optional
Shown directly to bottom-left of Main Control Board (A1) on silkscreen. Plugs into Main Board at
P13. Supports DNP3 and Modbus protocols via 10/100 copper Ethernet connection.
C2-Eliminator F
C2-Eliminator Filter Capacitor – optional
ilter Capacitor – optional
Shown below Power Board on silkscreen. Mounted on bottom-left under Power Board. Provides
the additional ripple filtering required for the 'filtered eliminator' option.
CB1-
CB1-A A C Input Cir
C Input Circuit Br
cuit Break
Located in center of ATevo, about one third from bottom. Protects ATevo ac wiring, and can be
used to disconnect from its ac source.
CB2-DC Output Cir
CB2-DC Output Circuit Br
cuit Break
Located at bottom-center below AC breaker. Protects ATevo dc wiring, and can be used to
disconnect ATevo from battery and system dc load(s).
L1-Main F
L1-Main Filter Inductor
ilter Inductor
Shown in center of silkscreen. Located on bottom-left of back wall. It is part of the dc filter,
lowering ripple
L2-Secondary F
L2-Secondary Filter Inductor
ilter Inductor
Shown bottom-center of silkscreen. Located on bottom of back wall to right of Filter Inductor
(L1). It is also part of the dc filter.
Copyright HindlePower Inc. 2021
ATevo Operations–Single Phase Input–Group II (30-100 Adc Output) - 1_en
MOV V Boar
Board d
e Pr r obe – optional
obe – optional
dapter
dapter – optional
eaker er
eaker er
dapter – optional
Page 29 of 171