Inlet Valve - Diesel WARTSILA F 240 Manual

Table of Contents

Advertisement

Manual
F 240

Inlet valve

Ver. 01
CAMSHAFT
19A
CHECKING VALVE TIMING
6. Measuring the cam lifting:
6. 1. Place the dial gauge on the inlet rocker arm exactly above the pushrod.
6. 2. Set the dial gauge to 0 mm.
6. 3. Turn the engine in the direction of rotation until the dial gauge indicates 4.03
mm.
6. 4. Take a reading of the number of crank degrees. The value found has to be 19
before Top Dead Centre, permitted tolerance is 1
7. If the setting is not correct please consult the Service Department of Stork
Wärtselä Diesel. If the setting of the cam is correct, adjust the valve clearance. The
setting values are specified in Technical Data.
--o--o--o--o--o--
o
).
19 - - 2
o

Advertisement

Table of Contents
loading

Related Products for Diesel WARTSILA F 240

Table of Contents