General Diagram - Diesel WARTSILA F 240 Manual

Table of Contents

Advertisement

Manual
F 240
1. Starting system
2. Stopping device
3. Pneumatic pump
4. Miscellaneous
Explanation
letters
Ver. 01
STARTING AND STOPPING SYSTEM
9D
9D

GENERAL DIAGRAM

GENERAL DIAGRAM
Explanation of the numbers in the diagram, of a 6 cylinder clockwise turning engine for
operation on MDO. The pipelines between the engine parts 1.2 to 1.5 are for starting air,
the other pipelines are for pilot air.
No.
Name
1. 1. Air compressor
1. 2. Air bottle
1. 3. Starting air intermediate valve, (manual and/or electrically
controlled)
1. 4. Safety valve
1. 5. Starting valve (per cylinder)
1. 6. Air distributor
2. 1. Non return valve
2. 2. Electric/pneumatic three--way valve (for overspeed security)
2. 3. Stopping cylinder
2. 4. Fuel control shaft
3. 1. Pneumatic pump
3. 2. Electric/pneumatic four--way valve
3. 3. Reducing valve
4. 1. Needle valve
4. 2. Filter/water seperator
4. 3. Reducing valve
PAL Pressure alarm Low
PI
Pressure indicator
PS
Pressure switch
4.2
1.2
1.1
4.1
1.6
1.3
3.2
4.1
2.1
4.3
--o--o--o--o--o--
1.4
1
2
3
3.1
2.2
3.3
2.3
1.5
4
5
6
2.4
9 - - 5