Error Assistance
Display COMBIVIS
A. OH
A.STOP overheat pow.mod
A.OH2
ABN.STOP motor protect.
A.OHI
ABN.STOP overheat int.
A. OL
ABN.STOP overload
A.OL2
ABN.STOP overload 2
A.PrF
ABN.STOP prot. rot. for.
A.Prr
ABN.STOP prot. rot. rev.
A.SbuS ABN.Bus synchron
A.SEt
ABN.STOP set
A.SLF
ABN.Software limit switch forward
A.SLr
ABN.Software limit switch reverse
Chapter
Section
Page
9
1
8
Value Meaning
100 The warning is output when the standstill continuous current
103 Synchronization over sercos-bus not possible. The response
102 Warning: set selection: It has been attempted to select a
104 The right software limit switch lies outside the defined limits.
105 The left software limit switch lies outside the defined limits.
Date
Name: Basis
10.04.02
KEB COMBIVERT F5
89 A level can be defined, when it is exceeded this warning is
output. A response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
97 Warning: electronic motor protective relay has tripped. The
response to this warning can be programmed (see chapter
6.7 "Response to error or warning messages").
87 The temperature in the interior of the inverter lies above the
permissible level. The switch off time was started. The
programmed response to this warning message is executed
(see chapter 6.7 "Response to errors or warning messages").
99 A level between 0 and 100 % of the load counter can be
adjusted, when it is exceeded this warning is output. The
response to this warning can be programmed (see chapter
6.7 "Response to errors or warning messages").
is exceeded (see technical data and overload
characteristics). The response to this warning can be
programmed (see chapter 6.7 "Response to errors and
warning messages"). The warning message can only be reset
after the cooling time has elapsed and A.nOL2 is displayed.
94 The drive is driven onto the right limit switch. The response
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
95 The drive is driven onto the left limit switch. The response to
this warning can be programmed (see chapter 6.7 "Response
to errors and warning messages").
to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages").
locked parameter set. The response to this warning can be
programmed (see chapter 6.7 "Response to errors or warning
messages").
The response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
The response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
©