Parameter Set Selection - KEB COMBIVERT F5 BASIC Applications Manual

Hide thumbs Also See for COMBIVERT F5 BASIC:
Table of Contents

Advertisement

Parameter Sets
6.8.7 Parameter Set
Selection
Fig. 6.8.7
Principle of parameter set selection
set selection
deactivated
always set 0 activ
Fr.3 Parameter set lock
Set 0...7 (Value 0...255)
Fr.2 Source parameter set
Fr.4 Adjustment parameter set
©
KEB Antriebstechnik,2002
All rights reserved
1
2
2
2
digital
Fr.4 via
terminal strip
keyboard / bus
binary coded
Parameter set 0...7
Actual Parameter set
As shown in Fig. 6.8.7, with Fr.2 it is defined whether the parameter set selection is
enabled or disabled via keyboard/Bus (Fr.4), the terminal strip or via control word
(SY.50). The selection is activated with „Enter".
Fr.2
Function
0
Set selection deactivated; set 0 always active
1
Set selection via keyboard/Bus with Fr.4
2
Set selection binary-coded via terminal strip
3
Set selection input-coded via terminal strip
Priority: ST>RST>R>F>I1>I2>I3>I4>IA>IB>IC>ID
4
Set selection input-coded via terminal strip
Priority: ID>IC>IB>IA>I4>I3>I2>I1>R>F>RST>ST
5
Set selection via control word SY.50
This parameter can be written by Bus as well as by keyboard. The desired parameter
set (0...7) is preadjusted directly as value and activated with „Enter".
Name: Basis
KEB COMBIVERT F5
Functional Description
0
2
7
6
5
4
3
2
1
terminal strip
input coded
ST>RST...>ID
2 3
4
1
5
0
Fr.2
Is
Error message
yes
selected set
locked?
no
7
6
5
4
3
2
1
terminal strip
Sy.50 with
input coded
control word
ID>IC...>ST
(only bus)
Attention! The valency at
Fr.2 = 2...4 is generally ID >
IC > ...>ST. The succession
describes at the inputs refers
to the priority.
E.SEt
Date
Chapter
Section
6
8
17.04.02
6
Page
5
5