Incremental encoder output
Operating mode
encoder 2 (ec.20)
Chapter
Section
Page
6
10
6
Signal
X3B
U
5
var
+5,2 V
4
0 V
9
A
1
_
A
6
B
2
_
B
7
N
3
_
N
8
Shield
Housing
The signal inputs of the second encoder interface support only rectangular signals.
Following specifications apply to the endocer interface 2 (X3B):
• max. operating frequency of input f
• internal terminating resistor R
• 2...5 V high level at rectangular signals
The incremental encoder output gives out the signals recorded at the encoder interface
1:1 in RS422-specification over the second channel (e.g. master drive in synchronous
operation).
Signal
X3B
U
5
var
+5,2 V
4
0 V
9
A
1
_
A
6
B
2
_
B
7
N
3
_
N
8
Shield
Housing
With parameter ec.20 it is defined whether the encoder channel 2 shall work as input
or output. Precondition for that is a built-in switch-selectable encoder interface
(In.5 = 7).
ec.20 Function
0
1
Date
Name: Basis
28.01.02
KEB COMBIVERT F5
Description
Supply voltage for encoder (see 6.10.2)
Supply voltage for encoder (see 6.10.2)
Reference potential
Signal input A
Signal input A inverted
Signal input B
Signal input B inverted
Reference marking input N
Reference marking input N inverted
Shielding
= 150 Ω
t
Description
Supply voltage for encoder (see 6.10.2)
Supply voltage for encoder (see 6.10.2)
Reference potential
Signal output A
Signal output A inverted
Signal output B
Signal output B inverted
Reference marking output N
Reference marking output N inverted
Shielding
Incremental encoder input
Incremental encoder output
Encoder Interface
= 300 kHz
G
©