CP - Parameter
Source of rotation direction
©
KEB Antriebstechnik, 2001
All Rights reserved
The source rotation setting and the mode of evaluating the rotation setting is defined
with this parameter (Enter-Parameter). With CP.34 one does not modify the rotation
source of the fixed frequencies (CP.19... 21).
Value
Function
0/1
Only application mode
2
Setting by way of terminal strip forward/reverse; negative set values are
set to zero (factory setting)
3
Setting by way of terminal strip forward/reverse; the signs of the setpoint
values have no effect on the direction of rotation
4
Setting by way of terminal strip run/stop (X2A.14) and forward/reverse
(X2A.15); negative values are set to zero
5
Setting by way of terminal strip run/stop (X2A.14) and forward/reverse;
the signs of the setpoint values have no effect on the direction of rotation
6
Set value dependent, positive value - clockwise rotation; negative value-
counterclockwise rotation; with set value "0" it is switched into status
"Low speed" (LS)
7
Set value dependent, positive value - clockwise rotation; clockwise
rotation is indicated
8/9
Only application mode
Set value
0-limited
(Value 2 and 4)
-100%
-10V
Set value
absolute
(Value 3 and 5)
-100%
-10V
Adjustment range:
Resolution:
Factory setting:
Note:
Name: Basis
KEB COMBIVERT F5-G / B
Operation
internal
intern
10V
100%
extern
external
100%
-100%
intern
internal
10V
100%
extern
external
100%
-100%
Enter-Parameter
Date
04.12.01
0...9
1
2
Chapter
Section
Page
4
3
19
4
19