Analog In- and Outputs
6.2.7
Amplifier of the
Input Characterstic
(An.5...7; An.15...17;
An.25...27)
©
KEB Antriebstechnik, 2002
All rights reserved
With these parameters the input signals can be adapted in X and Y direction as well
as in the rise to the requirements. In the case of factory setting no zero point offset is
adjusted, the rise (gain) is 1, i.e. the input value corresponds to the output value of
this step (see Fig. 6.2.7.a) The output value is calculated according to following formula:
Out = Amplification • ( In - Offset X) + Offset Y
Fig. 6.2.7.a
Factory setting: no Offset, Gain 1
Input
AN1
AN2
Amplification An.5 An.15
Offset X
An.6 An.16
Offset Y
An.7 An.17
By means of some examples, we want to show the possibilities of this function.
According to Fig. 6.2.7.b
1. adjustment of the X-Offset for input AN1 to 50 (%)
2. adjustment of the amplificaiton to 2
Fig. 6.2.7.b
X-Offset (An.6)=50%; amplification (An.5)=2.00
1.
100%
An.6
-100%
-100%
50%
100%
-100%
Name: Basis
KEB COMBIVERT F5
Functional Description
Output value (Out)
100%
Input value (In)
-100%
100%
-100%
AN3
Value range
An.25
-20,00...20,00
An.26 -100,0%...100,0%
An.27 -100,0%...100,0%
2.
100%
With these settings the entire speed
range can be driven with 0...10 V
via input AN1.
An.5
(rotation direction = ±analog)
100%
0%
50% In corresponds to
100% In corresponds to 100% Out
-100%
Date
12.04.02
Resolution Default value
0,01
1,00
0,1%
0,0%
0,1%
0,0%
In corresponds to-100% Out
0% Out