Special Functions
Start value (Pn.37)
Stop value (Pn.41)
Used Parameters
R/W
PROG.
Param.
Adr.
Pn.34
0422h
Pn.35
0423h
Pn.36
0424h
Pn.37
0425h
0425h
Pn.39
0427h
Pn.40
0428h
Pn.41
0429h
0429h
Pn.43
042Bh
©
KEB Antriebstechnik, 2002
All rights reserved
The adjustable start/stop value stands in direct connection with the necessary holding
torque. The preadjustment, according to following formula, is valid for rated motor
torques:
Start-/Stop value=
(1500rpm - 1420rpm ) x 50Hz
Example:
The direction into which the holding torque shall take effect is determined by the sign.
The parameters are set-programmable.
At using the brake control the direction of rotation (oP.1) may not be set to „7", because
then no Low-Speed-Signal (LS) is output.
ENTER
max
min
0
4
-
0,00 s
100,00 s
-
0,00 s
100,00 s
-
-20 Hz
20 Hz
-
-600 rpm
600 rpm
-
0,00 s
100,00 s
-
0,00 s
100,00 s
-
-20 Hz
20 Hz
-
-600 rpm
600 rpm
-
0
100 %
Name: Basis
KEB COMBIVERT F5
Functional Description
(no-load motor speed - rated motor speed) x rated motor frequency
1500rpm
Step
default
1
0
0,01 s
0,25 s
0,01 s
0,25 s
0,0125 Hz
0 Hz
0,125 rpm
0 Hz
0,01 s
0,25 s
0,01 s
0,25 s
0,0125 Hz
0 Hz
0,125 rpm
0 Hz
1 %
0 %
no-load motor speed
= 2,67 Hz
-
-
-
F5-G/B depending on ud.2
F5-M/S depending on ud.2
-
-
F5-G/B depending on ud.2
F5-M/S depending on ud.2
-