Functional Description
6.3.22 Inversion of Out-
puts (do.42)
6.3.23 Output Terminal
Status (ru.25)
Chapter
Section
Page
6
3
18
As shown in Fig. 6.3.21, with parameter do.42 the outputs can be once again inverted
after the linking. The parameter is bit-coded, i.e. according to following table the value
belonging to this output must be entered. If several outputs shall be inverted the sum
is to be formed
Fig. 6.3.21 Inverting the outputs
Bit 0
Bit 1
Bit 2
Bit 3
do.41
Bit 4
Bit 5
Bit 6
Bit 7
The output terminal status shows the logical status of the digital outputs. It is unimportant
whether the output is set on the basis of conditions or by inversion. If an output is set,
the appropriate decimal value, according to the table below, is output. If several outputs
are set, then the sum of the decimal values is output.
Terminal
X2A.18
X2A.19
X2A.24...26
X2A.27...29
-
-
-
-
Date
Name: Basis
16.04.02
KEB COMBIVERT F5
do.42
Terminal
1
1
X2A.18
2
1
X2A.19
4
1
X2A.24...26
8
1
X2A.27...29
16
1
-
32
1
-
64
1
-
1
128
-
Name
Function
O1
Transistor output
O2
Transistor output
R1
Relay output
R2
Relay output
OA
Internal output
OB
Internal output
OC
Internal output
OD
Internal output
Digital In- and Outputs
Name
Function
O1
Transistor output
O2
Transistor output
R1
Relay output
R2
Relay output
OA
Internal output
OB
Internal output
OC
Internal output
OD
Internal output
Decimal values ru.25
1
2
4
8
16
32
64
128
©