Functional Description
Diameter correction dmin/dmax
(oP .49)
Additional function
Acceleration/Deceleration
(oP .46)
Used Parameters
R/W
PROG.
Param.
Adr.
oP.44
032Ch
oP.45
032Dh
oP.46
032Eh
oP.49
0331h
Chapter
Section
Page
6
9
30
The diameter signal is evaluated within the range of 0% to 100%. Values < 0% are set
to 0%, values > 100% are limited to 100%.
The diameter signal of 0% corresponds to the minimum diameter of the reel bale
(d
). The output speed of the ramp generator is not changed in this case. A diameter
min
signal of 100% corresponds to the maximum diameter of the reel bale (d
to be able to calculate the speed change the program requires the ratio of minimum to
maximum diameter (d
The ratio of minimum to maximum diameter (d
can be adjusted within the range of 0.010...0.990 with a resolution of 0.001.
The corrected output frequency of the ramp generator is determined as follows:
fn_presetting = –––––––––––––––––
fn_Ramp:
fn_presetting:
DS:
oP.49:
The rate of change of the diameter signal can be limited by a ramp generator. By way
of oP.46 the time can be preset within the range of 0.0...20 s, which is required for a
signal difference of 0...100%.
ENTER
min
-
0
63
-
-
0,00 %
100,00 %
-
-
0,00 s
20,00 s
-
0,010
0,990
Date
Name: Basis
18.04.02
KEB COMBIVERT F5
/d
).
min
max
fn_Ramp
1+DS·(1/oP.49-1)
Output freqency/speed of ramp generator
Corrected output frequency/speed
Diameter signal 0 - 100% (0 to 1)
(d
/d
)
min
max
Step
max
default
1
0
0,01 %
0,00 %
0,01 s
10,00 s
0,001
0,500
Special Functions
max
/d
) is preset by way of oP.49 and
min
max
-
-
-
-
©
KEB Antriebstechnik, 2002
All rights reserved
). In order