KEB COMBIVERT F5 BASIC Applications Manual page 179

Hide thumbs Also See for COMBIVERT F5 BASIC:
Table of Contents

Advertisement

Motor Data Adjustment
6.6 Motor Data
Adjustment
6.6.1
Motor Name Plate
Fig. 6.6.1
Example of a motor name plate
DK 160 L 4 F I
dr.3
3
dr.2
dr.5
50
Hz
ϕ
dr.4
cos
dr.1
U
FL
3
6.6.2
Motor Data from
the Name Plate
(dr.0...dr.5)
©
KEB Antriebstechnik, 2002
All rights reserved
The adjustment of the correct motor data is important for many inverter functions,
since calculations are derived from it, which the inverter requires to achieve the best
possible results in the control of Boost and slip compensation.
KEB Antriebstechnik
GmbH & Co. KG
Schneeberg
ANTRIEBSTECHNIK
/TW150
96/1632804/ 001
-Mot IP
55
IM
B 3
VDE 053 0
15,0 KW
230/400
V
0,86
1455
230/400
V
~Mot
50
Hz
M
Br
Following parameters can be taken directly from the name plate (see above) and
entered:
- dr.0
Rated motor current
- dr.1
Rated motor speed
- dr.2
Rated motor voltage
- dr.3
Rated motor power
- dr.4
Rated motor power factor
- dr.5
Rated motor frequency
Parameter dr.0 and dr.2 are always to be adjusted according to the used
wiring (star/delta). For above stated motor name plate that is 230 V / 49.5 A
at delta-connection and 400 V / 28.5 at star-connection
Name: Basis
KEB COMBIVERT F5-G / B
Funtional Description
Made in
Germany
W.KI.
F
/Y
49,5/28,5
A
1/min
IGR 05B
2500 Imp
5V D0/RS
Nm
I
Sp max
0.0...710.0 A (Star-/Delta-connection)
0...64000 rpm
120...500 V (Star-/Delta-connection)
0.35...400.00 kW
cos(phi) 0.00...1.00
0...1600.0 Hz
40
°C
127
kg
6xTTL
mm
Date
Chapter
Section
6
6
23.01.02
6
dr.0
Page
3