Canon imageRUNNER ADVANCE C3330 Series Service Manual page 560

Hide thumbs Also See for imageRUNNER ADVANCE C3330 Series:
Table of Contents

Advertisement

246-0003-00
Detection Description
Remedy
246-0005-00
Detection Description
Remedy
247-0001-00
Detection Description
Remedy
247-0002-00
Detection Description
Remedy
247-0003-00
Detection Description
Remedy
247-0004-00
Detection Description
Remedy
248-0001-04
Detection Description
Remedy
260-0001-05
Detection Description
Remedy
System error
System error
Contact to the sales company.
System error
System error
Contact to the sales company.
System error
System error
Contact to the sales company.
System error
System error
Contact to the sales company.
System error
System error
Contact to the sales company.
System error
System error
Contact to the sales company.
EEPROM error
The Controller IC of the Main Controller PCB detected an error at reading or rewriting of the Reader
backup value in the Scanner Unit.
[Related parts]
- Flat Cable between the Main Controller PCB (UN05/J33) and the Scanner Unit (Unit of
replacement: CABLE, FLAT)
- Harnesses from the Main Controller PCB to the ADF Driver PCB
1. Main Controller PCB (UN05/J38) to Relay Connector (2P) (Unit of replacement: CABLE, ADF
POWER CONNECTING)
2. Relay Connector (2P) to ADF Driver PCB (PCB1/J1411)
- Scanner Unit (Unit of replacement: LASER SCANNER ASSEMBLY)
- Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
- ADF Driver PCB (PCB1)
[Remedy] Check/replace the related harness/cable, connector and parts.
Power supply error
Short-circuit was detected at power-on.
[Related parts]
- Harness between the DC Controller PCB (UN04/J100 and J115) and the Low Voltage Power
Supply PCB (UN01/J315 and J322) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
548
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents