COPIER (Service mode for copier) > OPTION (Specification setting mode) > DSPLY-SW
ITB-DSP
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Additional Functions
Mode
UI-CUSTM
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
CLN-SEL
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
USER-DSP
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
ON/OFF ITB on init scrn after prts rplce
To set whether to display "ITB" on the initialization screen after replacing parts in Settings/
Registration menu.
When allowing the user to replace the ITB, set 1.
When allowing the user to replace the ITB
Enter the setting value, and then press OK key.
0 to 1
0: OFF, 1: ON
0
Adjustment/Maintenance> Maintenance> Initialize After Replacing Parts> ITB
ON/OFF of Quick Menu screen display
To set whether to display the Quick Menu screen on the Control Panel.
When not displaying the Quick Menu screen on the Control Panel
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: OFF, 1: ON
1
Set condensation prev:Clean Condensation
To set the effect of the condensation cleaning for condensation prevention.
When 0 is set, "Clean Condensation" is not displayed in Settings/Registration menu.
When 1 to 3 is set, "Clean Condensation" is displayed and the level of the effect of condensation
cleaning can be set.
As the value is larger, the effect is increased because the condensation cleaning is executed more
frequently, but cleaning time are increased.
In the case of installation in a low temperature and high humidity environment (in winter), ask for
the user's opinion and configure the setting.
When condensation occurs in a low temperature and high humidity environment
Enter the setting value, and then press OK key.
0 to 3
0: OFF
1: ON (small effect, short cleaning time)
2: ON (moderate effect, medium cleaning time)
3: ON (large effect, long cleaning time)
0
Set of SSO-H login user name display
To set whether to display the name of the user who logs in using MEAP authentication (SSO-H)
on the upper left area of the Control Panel screen.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 2
0: Hide, 1: Display "display name", 2: Display "user name"
0
MEAP authentication (SSO-H): local authentication and server authentication using the Single
Sign On-Hybrid MEAP application.