Canon imageRUNNER ADVANCE C3330 Series Service Manual page 546

Hide thumbs Also See for imageRUNNER ADVANCE C3330 Series:
Table of Contents

Advertisement

025-0268-05
Detection Description
Remedy
025-0310-05
Detection Description
Remedy
025-0320-05
Detection Description
Remedy
No toner detection error (M)
- The state without toner was detected although the recovery sequence was performed for 5 times
after replacement of the Toner Container (M).
- The recovery sequence was repeated with no toner in the container.
[Related parts]
- Toner Container (M)
- Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M)
- Developing Unit (M) (UN22) (Unit of replacement: DEVELOPING ASSEMBLY, M)
- ITB Rail Rear Unit (Unit of replacement: I.T.B. RAIL ASSEMBLY, REAR)
[Remedy] Be sure to perform the following procedure.
1. Shake the Toner Container 10 times, and then insert it into the host machine.
2. Check/replace the related harness/cable, connector and parts.
Bottle Motor error (C)
The Toner Supply Sensor (C) did not detect change for 1 sec or longer while the Bottle Motor (CK)
was rotated at toner supply.
[Related parts]
- Harnesses from the Bottle Motor (CK) to the DC Controller PCB
1. Bottle Motor (CK) (M05) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE
MOTOR)
2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER
BOTTLE)
- Harness between the Toner Supply Sensor (C) (PS28/J1061) and the DC Controller PCB (UN04/
J127) (Unit of replacement: CABLE, TONER BOTTLE)
- Toner Supply Sensor (C)
- Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Bottle Motor error (C)
Rotation of bottle was detected while the Toner Bottle Motor (C) was OFF.
[Related parts]
- Harnesses from the Bottle Motor (CK) to the DC Controller PCB
1. Bottle Motor (CK) (M05) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE
MOTOR)
2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER
BOTTLE)
-Harness between the Toner Supply Sensor (C) (PS28/J1061) and the DC Controller PCB (UN04/
J127) (Unit of replacement: CABLE, TONER BOTTLE)
- Toner Supply Sensor (C)
- Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES