Canon imageRUNNER ADVANCE C3330 Series Service Manual page 619

Hide thumbs Also See for imageRUNNER ADVANCE C3330 Series:
Table of Contents

Advertisement

733-0001-05
Detection Description
Remedy
733-0002-05
Detection Description
Remedy
733-0F00-05
Detection Description
Remedy
733-0F01-05
Detection Description
Remedy
733-0F02-05
Detection Description
Remedy
733-F001-05
Detection Description
Remedy
Printer communication error
- DDI-P communication error
- DDI-L communication error (parity error)
[Related parts]
- Harness between the DC Controller PCB (UN04/J110) and the Main Controller PCB (UN05/J18)
(Unit of replacement: DDIP, CABLE)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
- Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the harness between the DC Controller PCB and the Main Controller PCB.
2. Turn ON the power, and check if the initialization is executed at startup.
2-1. If the initialization is not executed, replace the DC Controller PCB.
2-2. If the initialization is executed, replace the Main Controller PCB.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Printer communication error
DDI-P communication error (invalid packet) was detected.
[Related parts]
- Harness between the DC Controller PCB (UN04/J110) and the Main Controller PCB (UN05/J18)
(Unit of replacement: DDIP, CABLE)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
- Main Controller PCB (UN05) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the harness between the DC Controller PCB and the Main Controller PCB.
2. Turn ON the power, and check if the initialization is executed at startup.
2-1. If the initialization is not executed, replace the DC Controller PCB.
2-2. If the initialization is executed, replace the Main Controller PCB.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0000 is generated.
[Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted
after log collection.
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0001 is generated.
[Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted
after log collection.
Printer communication error
Communication error that can be recovered by reboot
If it is detected again immediately after reboot, E733-0002 is generated.
[Remedy] It is not necessary to perform a remedy because the machine is automatically rebooted
after log collection.
Printer communication error
Disconnection of a cable between the Main Controller PCB and the DC Controller PCB was
detected.
[Remedy] Check/replace the harness between the DC Controller PCB (UN04/J110) and the Main
Controller PCB (UN05/J18). (Unit of replacement: DDIP, CABLE)
607
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading

Table of Contents