2. The value calculated in step 1) is added to the Drum count value that has been stored in the IC tag of the Drum Unit.
NOTE:
The life (displayed in %) can be checked by the following service mode:
COPIER > COUNTER > LF > Y/M/C/K-DRM-LF : Drum counter life display (Y/M/C/Bk)
Timing
Detected to (location)
Message (Operation of the host
machine)
Alarm code
*1: (Lv.1) COPIER > COUNTER> LF > Y/M/C/K-DRM-LF
*2: (Lv.1) COPIER > OPTION > FNC-SW > D-DLV-CL/BK
*3: Display/Hide can be switched in (Lv.2) COPIER > OPTION > USER > P-CRG-LF (0: Hide)
*4: During the period from when a pre-toner low alarm is sent to when a replacement completion alarm is sent, the next pre-
toner low alarm is not sent. Displayed in COPIER > DISPLAY > ALARM-2
*5: Displayed in COPIER > DISPLAY > ALARM-3
DC Controller PCB
(UN04)
Life Information
Drum Unit
Memory PCB
(UN35〜38)
Drum Unit Memory
Prior delivery alarm
• Y/M/C/K-DRM-LF (*1) =
100% (initial value)
The value can be changed in
service mode.(*2)
Drum Unit New/Old Sensor
None
40-0070 (Y)
40-0071 (M)
40-0072 (C)
40-0073 (Bk) (*4)
Display to prompt replace-
ment
7 days after pre-toner low alarm
is sent (Default: Hide (*3))
-
Replace the drum unit (1/2/3/4). None
None
69
2. Technology
Completion of replacement
When the Drum Unit is detected
Drum Unit New/Old Sensor
35-0070 (Y)
35-0071 (M)
35-0072 (C)