073-0001-05
Detection Description
Remedy
074-0001-05
Detection Description
Remedy
Interlock error
The Interlock (24 V) was not detected although all the doors of the host machine were closed.
[Related parts]
- Harnesses from the Interlock Switch 1 and 2 to the DC Controller PCB
1. Interlock Switch 1 and 2 (SW02 and SW03) to Relay Connector (9P) (Unit of replacement:
CABLE, INTERLOCK SWITCH)
2. Relay Connector (9P) to DC Controller PCB (UN04/J133) (Unit of replacement: CABLE,
SENSOR)
- Harness between the Low Voltage Power Supply PCB (UN01/J315 and J322) and the DC
Controller PCB (UN04/J100 and J115) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
ITB HP time out error
The HP Sensor in the Main Drive Unit did not detect home position within the specified period of
time.
[Related parts]
- Harnesses from the DC Controller PCB to the Primary Transfer Roller Disengagement HP Sensor
1. DC Controller PCB (UN04/J131) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN
DRIVE)
2. Relay Connector (3P) to Primary Transfer Roller Disengagement HP Sensor (PS33/J1189) (Unit
of replacement: CABLE, SENSOR)
- Harness between the DC Controller PCB (UN04/J131) and the Primary Transfer Roller
Disengagement Motor (M08/J1201) (Unit of replacement: CABLE, MAIN DRIVE)
- Harness between the DC Controller PCB (UN04/J129) and the Bk Drum_ITB Motor (M02/J1054)
(Unit of replacement: CABLE, MAIN DRIVE)
- Primary Transfer Roller Disengagement HP Sensor (PS33)
- Primary Transfer Roller Disengagement Motor (M08)
- Bk Drum_ITB Motor (M02)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
- Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
- ITB Unit (Unit of replacement: INTER. TRANSFER BELT ASS'Y)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES