Canon imageRUNNER ADVANCE C3330 Series Service Manual page 899

Hide thumbs Also See for imageRUNNER ADVANCE C3330 Series:
Table of Contents

Advertisement

COPIER (Service mode for copier) > OPTION (Specification setting mode) > IMG-FIX
TMP-TBL3
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TBL4
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TBL5
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
TMP-TBL6
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
Set fixing control temp: heavy paper 2
To set the offset of fixing control temperature for heavy paper 2 (129 to 163 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When a fixing failure/fixing offset occurs on heavy paper 2
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temp: heavy paper 3
To set the offset of fixing control temperature for heavy paper 3 (164 to 220 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When a fixing failure/fixing offset occurs on heavy paper 3
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temperature: thin ppr
To set the offset of fixing control temperature for thin paper (52 to 63 g/m2).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When a fixing failure/fixing offset occurs on thin paper
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
Set fixing control temperature: envelope
To set the offset of fixing control temperature for envelope.
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
When a fixing failure/fixing offset occurs on envelope
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
deg C
0
5
887
8. Service Mode

Advertisement

Table of Contents
loading

Table of Contents