(2) How to Set the Function Using Switches
To set functions using the switches, follow the procedures below.
1.
Load thermal paper in the printer.
Ensure that no error occurs, and then turn off the printer.
2.
Hold the FEED Switch down and press the POWER Switch, then release the POWER Switch first.
Keep pressing the FEED Switch until the test print is completed.
3.
A message of mode selection is printed as shown in Figure 4-2 when the test print has completed.
To enter the Setting Mode, press the FEED Switch.
4.
A message for selecting MS to be set is printed as shown in Figure 4-3 when the printer enters the
Setting Mode.
Press the FEED Switch the number of times corresponding to the selected MS number, and then press
the POWER Switch.
・When pressing the FEED Switch once, "1 : MS1" is selected.
・When pressing the POWER Switch without pressing the FEED Switch, "0 : Exit" is selected.
[Enter Setting Mode]
Enter Setting Mode: Feed SW
Exit: Power SW

Figure 4-2 Mode Selection Message

[MS Selection]
0 : Exit
1 : MS1
2 : MS2
3 : MS3
4 : MS4
5 : MS5
6 : MS6
7 : MS7
8 : MS13
9 : MS17
10: MS18
11: I/F Setting
12: International Character
13: Character Code Table
14: Default Setting
Press the FEED switch an equal
number of times to the selected number.
After that, press the POWER SW.

Figure 4-3 MS Selection Message

4-3