Function Settings (Ms); Table 4-1 General Setting 1 (Ms1); Table 4-2 Standby Led Selection (Ms1-4 To 5) - Seiko RP-F10 Series Technical Reference

Table of Contents

Advertisement

4.2 FUNCTION SETTINGS (MS)

Details of each function are described below. The value shown in the shaded cell (in bold) in the table is
set at the shipping.
(NOTE) Be sure to configure the setting or the value as instructed when "Fixed" is stated
in the table.
For reserved area, be sure to set the specified value. Otherwise, the printer may
not work correctly or may crush. Reserved values may be changed.
1.
General Setting 1 (MS1)
Sets the printer and selects the peripheral device.
• Standby LED Selection (MS1-4)
The LED color in the standby mode can be selected.
• Auto Activation by AC Selection (MS1-7)
When this function is enabled, inserting the AC cable of the specified AC adapter into a socket can
turn on the printer.
• POWER Switch Function Selection (MS1-8)
Enables or disables the POWER Switch of the printer.
MS
1-1 to 3 Reserved
1-4 to 5
1-6
1-7
1-8

Table 4-1 General Setting 1 (MS1)

Function
Standby LED Selection
(Standby LED)
Reserved
Auto Activation by AC Selection
(Auto Activation by AC)
POWER Switch Function Selection
(Power SW)

Table 4-2 Standby LED Selection (MS1-4 to 5)

MS2-2
MS2-1
0
0
0
1
1
0
1
1
0
-
See Table 4-2
-
Disable
Disable
Standby LED
Aqua
Green
Off
Blue
4-6
Value
1
Fixed
Fixed
Enable
Enable