Store Qr Code Data; Encode And Print Qr Codel Data - Seiko RP-F10 Series Technical Reference

Table of Contents

Advertisement

GS '(' 'k' pL pH cn fn m [d]k
Code
1DH 28H 6BH pL pH cn fn m [d] k
Definition Range
Function Stores the QR Code data (d1 to dk) in the memory.
Notes
This command is ignored when any value out of the definition range is specified.
This setting does not affect GS 'p' 1.
Related Commands GS '(' 'k', GS 'p' 1
GS '(' 'k' pL pH cn fn m
Code
1DH 28H 6BH pL pH cn fn m
Definition Range
Function Performs encoding and printing the QR Code data that stores in the memory depending on
the setting of following commands.
Select QR Code Model (GS '(' 'k' pL pH '0' fn n1 n2)
Set QR Code Module Size (GS '(' 'k' pL pH cn fn n1 n2)
Select QR Code Error Correction Level (GS '(' 'k' pL pH cn fn m)
The version is automatically selected.
Mode of data is fixed to the mixed mode.
Notes
This command is ignored when any value out of the definition range is specified.
When the horizontal width of QR Code exceeds the print area, this command is ignored.
In the standard mode, when there is data in the line buffer, this command is ignored.
In the standard mode, alignment and inversion (flip) printing are valid.
Quiet zones are not secured. Set the quiet zone in accordance with the standard of each
barcode system.
Related Commands GS '(' 'k'
4 ≤ (pL+pH×256) ≤ 7092
cn = 49
fn = 80
m = 48
0 ≤ d ≤ 255
1 ≤ k (= pH × 256 + pL - 3) ≤ 7089
pL = 3, pH = 0
cn = 49
fn = 81
m = 48
Encode and Print QR Code Data
6-75

Store QR Code Data

Advertisement

Table of Contents
loading

Table of Contents