Del Dc4 Fn A N R T1 T2; Stop External Buzzer; Set External Buzzer - Seiko RP-F10 Series Technical Reference

Table of Contents

Advertisement

The Bluetooth PIN code setting is completed when the number of setting data bytes exceeds
16 bytes or NULL is detected in the setting data.
When the number of setting data bytes exceeds 16 bytes, the 17th character is considered as
NULL character, and the following data is processed as character code.
When the number of setting data bytes is less than 4 bytes, it is ignored.
The characters available for setting Bluetooth device name or PIN code are as follows:
'0' to '9', 'a' to 'z', 'A' to 'Z', '+', '-', '_', '#', '*', ' '(space:20H)
Characters other than above are ignored.
After setting the Bluetooth device name or PIN code, turn on the printer again or execute
hardware reset.

DEL DC4 fn a n r t1 t2

Code
10H 14H fn a n r t1 t2
Definition Range
Function Stops the following beeping of the external buzzer.
・ Auto beeping when an error occurs or when cut process completes
・ Beeping by "Generate Pulse" command (ESC 'p')
・ Beeping by "Generate Pulse in Real Time" command (DLE DC4 fn)
・ Beeping by "Stop External Buzzer" command (ESC '(' 'A' 1 pL pH fn n c)
Notes
This is a realtime command.
The operation of this command differs depending on the Function Setting MS13-3 (Realtime
Command Selection).
・ When the Function Setting MS13-3 (Realtime Command Selection) is enabled:
This command is valid.
Notes when using a realtime command:
The user should note that the same behavior as this command occurs when the code
line matching the code that comprises this command is received. For example,
graphics data contains such code line.
・ When the Function Setting MS13-3 (Realtime Command Selection) is disabled:
This command is ignored.
ESC '(' 'A' 1 pL pH fn n c
Code
1BH 28H 41H pL pH fn n c
Definition Range
Function Beeps the buzzer pattern specified by n the number of times specified by c.
Repeats the specified buzzer pattern indefinitely when c = 0.
Stops beeping when the following operations are performed while the buzzer beeps.
・ Open the paper cover.
・ Press the POWER Switch.
・ Press the FEED Switch.
・ Execute "Stop External Buzzer" command (DLE DC4 (fn=3)).
fn = 3
a = 0
n = 0
r = 0
t1 = 1, t2 = 0
pL = 3, pH = 0
fn = 97
0 ≤ n ≤ 3
0 ≤ c ≤ 255
6-105

Stop External Buzzer

Set External Buzzer