14. General Setting 18 (MS18)
Sets the external buzzer to beep with "Generate Pulse" command (ESC 'p') and "Generate Pulse in
Real Time" command (DLE DC4 fn).
• Buzzer Count Selection (MS18-1 to 2)
The beeping times can be selected.
• Buzzer Pattern Selection (MS18-3 to 4)
The buzzer pattern of can be selected.
• Buzzer Volume Selection (MS18-5)
The buzzer volume can be selected.
Low: Beeps at buzzer drive frequency 1kHz.
Loud: Beeps at buzzer drive frequency 4kHz.
MS
Buzzer Count Selection
18-1 to 2
(Buzzer Count)
Buzzer Pattern Selection
18-3 to 4
(Buzzer Pattern)
Buzzer Volume Selection
18-5
(Buzzer Volume)
18-6 to 8 Reserved
15. Reserved (MS19 to 38)
MS19 to 38 are all reserved. To write all 40 bytes, send FFH as values of MS19 to 38.
Table 4-25 General Setting 18 (MS18)
Function
Table 4-26 Buzzer Count Selection (MS18-1 to 2)
MS18-2
MS18-1
0
0
0
1
1
0
1
1
Table 4-27 Buzzer Pattern Selection (MS18-3 to 4)
MS18-4
MS18-3
0
0
0
1
1
0
1
1
0
See Table 4-26
See Table 4-27
Low
-
Buzzer Count
None
Once
Thrice
Five Times
Buzzer Pattern
Pattern1
Pattern2
Pattern3
Pattern4
4-19
Value
1
Loud
Fixed