Set Barcode Height; Set Barcode Width - Seiko RP-F10 Series Technical Reference

Table of Contents

Advertisement

GS 'h' n
Code
1DH 68H n
Definition Range
Default
n = 162
Function Sets the barcode height to n dots.
Notes
When the value less than the GS1 Databar standard is specified, it is automatically adjusted
to the minimum height of each GS1 Databar.
Related Commands GS 'k'
GS 'w' n
Code
1DH 77H n
Definition Range
Default
n = 3
Function Sets the barcode width in dots.
n
2
3
4
5
6
Notes
Multilevel barcode refers to the following barcode systems:
UPC-A, UPC-E, JAN13 (EAN13), JAN8 (EAN8), CODE93, CODE128, JAN13 add-on
GS1 Databar Omni-directional, GS1 Databar Truncated, GS1 Databar Limited,
GS1 Databar Expanded
Binary level barcode refers to the following barcode systems:
CODE39, ITF, CODABAR
The wide element of the binary level barcode varies depending on the setting of the barcode
N:W ratio.
Set 3 or greater to n when the bars are parallel to the thermal paper feed direction. When 2 is
set to n, the reading accuracy may degrade.
Related Commands GS 'k', DC2 ':'
1 ≤ n ≤ 255
2 ≤ n ≤ 6
Multilevel Barcode Module
Width (mm)
0.250
0.375
0.500
0.625
0.750
Binary Level Barcode Narrow
Element (mm)
0.250 (2 dots)
0.375 (3 dots)
0.500 (4 dots)
0.625 (5 dots)
0.750 (6 dots)
6-60