82-06: Isdn Bri&Pri Layer3 (S-Point) Timer Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-06: ISDN BRI&PRI Layer3 (S-Point) Timer Setup to set the basic
timer for the layer 3 of ISDN BRI & PRI S-Point.
Input Data
Input Data
Programming Manual
82-06: ISDN BRI&PRI Layer3 (S-point) Timer Setup
Layer3 Timer Type No.
Item No.
Item
01
T301
02
T302
03
T303
04
T304
05
T305
06
T306
07
T307
08
T308
09
T309
10
T310
11
T312
12
T313
13
T314
14
T316
15
T317
16
T318
17
T319
18
T320
Input Data
0, 180~254(sec9
1~254(sec)
1~254(sec)
0~254(sec)
1~254(sec)
0~254(sec)
1~254(sec)
1~254(sec)
1~254(sec)
0~180(sec)
1~254(sec)
1~254(sec)
1~254(sec)
(T317 + 1) ~254(sec)
1~(T316-1)(sec)
1~254(sec)
1~254(sec)
1~254(sec)
Issue 10.1
1~ 5
Default
180(sec)
10(sec)
4(sec)
20(sec)
30(sec)
30(sec)
180(sec)
4(sec)
90(sec)
30(sec)
6(sec)
4(sec)
4(sec)
120(sec)
60(sec)
4(sec)
4(sec)
30(sec)