34-11: E1 Trunk Basic Setup (Ot) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 34-11: E1 Trunk Basic Setup to define the basic setting of each E1
Trunk.
Input Data
Item
No.
01
02
03
Programming Manual
Trunk Port Number
Name
E1 Trunk Type
Use this option to specify the
E1Signal type(0-8). Set this option
for compatibility with the
connected telco.
MFC Dialing Type
Use this option to specify the MFC
Dialing Type. The following table
shows the available MFC Dialing
Type choices, By default, this
option is 0 (MFC Dialing not used).
MFC Group B
Use this option to enable(1) or
disable(0) the MFC Dialing Group
B supervisory signaling. Since not
all central offices provide Group B
signaling, set this option for
compatibility with the connected
telco. By default, this option is
Disable(0).
Program 34 : Tie Line Setup

34-11: E1 Trunk Basic Setup (OT)

Input Data
0 = Standard Trunk
1 = Argentine Pulsed Clear Back Trunk
2 = Argentine Pulsed Answer Trunk
3 = Brazil With seizure acknowledge
Trunk
4 = Brazil Without seizure acknowledge
Trunk
5 = Brazil E&M Signal A(Idle=0) Trunk
6 = Brazil E&M Signal A(Idle=1) Trunk
7 = Brazil E&M Signal B(Idle=0) Trunk
8 = Brazil Code for collect call blocking
Trunk
0 = MFC Dialing not used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7= Venezuela
0 = Disable
1 = Enable
Issue 10.1
1~200
Default
0
0
0
2 - 465