Service Tone Timers - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 20-18: Service Tone Timers to set the values for the system service
tone timers. Refer to the following chart for a description of each option, its range and
default setting.
Input Data
Item
No.
01
02
03
04
05
06
07
08
09
Programming Manual
Program 20 : System Option Setup
Item
0~64800s
Extension Dial Tone
Time
0~64800s
Busy Tone Timer
0~64800s
Congestion Tone
0~64800s
Call Waiting Tone
Timer
0~64800s
Multiline Confirmation
Tone
0~64800s (OT)
Interval of Call
Waiting Tone
3~64800s (AU)
0~64800s
Intrusion Tone Repeat
Time
0~64800s
Conference Tone
Interval
0~64800s
Warning Beep Tone
Signaling Interval

20-18 : Service Tone Timers

Input Data
Default
30
15
10
10
10
10
0
0
60
Description
After getting Intercom dial
tone, a telephone user has
this time to dial the first
digit of the Intercom call.
A Busy Tone when system
resources run short. (such
as DTMF receiver
resources).
This option sets the time
between Call Waiting
tones. This timer also sets
the time between Off-Hook
Signaling alerts.
After a call is interrupted
(such as Barge-In, Voice
Mail Conversation
Recording, or Voice Over),
the system repeats the
Intrusion Tone after this
time. Normally, you should
enter 0 to disable this time.
Issue 10.1
Related
PRG
14-01-
18
2 - 275

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents